Ecol laboratory tests: RULER – determination of amine and phenolic inhibitor

  • Standards: ASTM D6971 Non-zinc Turbine Oils, ASTM D7590 Lubricating oils
  • Unit: %
  • Oil quantity: 1 ml
  • Application: turbine oils, hydraulic oils, compressor oils, gear oils, engine oils, heat transfer oils, lubricants
  • Scope of designation: 0-100%


  • Method description:

    RULER – Remaining Useful Life Evaluation Routine.

    Using the voltammetry technique, a diagram is plotted which, with reference to a reference curve, indicates the amount of antioxidant inhibitors remaining in the oil.



    Interpretation of results:

    This is the only method that allows the determination of levels of all types of antioxidants in oils. We use this method when using amine and phenolic additive technology in oils. Oil oxidation cannot be stopped, it can only be slowed down. Degradation of antioxidants dramatically accelerates oil oxidation.